Jinglufa’s 4-line CBRN decon tent is specifically engineered for Chemical, Biological, Radiological, and Nuclear (CBRN) emergency mass decontamination. Featuring four isolated parallel walk-through corridors—separating ambulatory male, ambulatory female, non-ambulatory stretcher casualties, and technical responders/equipment—and heavy-duty 1100g/m² airtight PVC air beams, it enables high-volume triage for defense, municipal, and hospital response teams.
Outer Dimensions: 6.0m (L) × 5.0m (W) × 2.8m (H)
Inner Clear Workspace: 6.0m (L) × 4.6m (W) × 2.35m (H)
Corridor Configuration: 4 Parallel Isolated Lanes (Male / Female / Stretcher / Responder)
Deployment & Wind Rating: 3–5 Minutes Setup | Grade 8–10 Wind Load (25 m/s)
Defense logistics officers, municipal emergency managers, and hospital CBRN directors deploy Jinglufa’s 4-line CBRN decon tent systems to achieve maximum casualty throughput and strict hot-zone isolation:
l Quad-Corridor Mass Triage: Four physically isolated lanes enable simultaneous, uncompromised processing of ambulatory male casualties, ambulatory female casualties, stretcher-bound patients, and hazmat responders/gear.
l Maximum CBRN Chemical & Fire Readiness: Certified to DIN 4102 B1/B2 flame-retardant standards and engineered with chemical-resistant textiles built to withstand aggressive decontaminants.
l 3–5 Minute Field Deployment: High-output 1200W electric air pump inflates the full 6.0m × 5.0m reinforced air frame in under 5 minutes for immediate mobilization in hot and warm zones.
l Severe Climate & Wind Resilience: Operates reliably across extreme temperatures from -20°C to +70°C while resisting wind loads up to 25 m/s (Grade 8–10) in exposed field deployments.
Built to endure extreme hazardous environments, our 4-line CBRN decontamination shelter spans a 6.0m × 5.0m footprint supported by 200mm diameter high-density 1100g/m² airtight PVC air columns and industrial-grade barrier textiles.
Specification Category | Technical Parameters & Material Standards |
Reinforced Air Beam Profile | 200mm diameter double-sealed 1100g/m² high-density PVC airtight mesh air columns; engineered for extreme internal pressure stability and vertical structural rigidity without metal poles. |
Outer Tent Fabric (Standard) | 400D Oxford fabric with single PU coating (PRO A Series, 230g/m²), certified DIN 4102 B1 flame retardant, 100% waterproof, chemical-resistant, and anti-corrosion. |
Outer Tent Fabric (Heavy-Duty Option) | 550g/m² double-sided PVC knife-coated polyester textile for maximum chemical barrier protection, abrasion durability, and extended field service life. |
Containment Floor System | Heavy-duty 650g/m² double-sided knife-coated PVC groundsheet with raised perimeter bunding edges to retain toxic CBRN runoff for controlled hazardous waste disposal. |
Outer Footprint Dimensions | 6.0m (Length) × 5.0m (Width) × 2.8m (Height) |
Inner Clear-Span Dimensions | 6.0m (Length) × 4.6m (Width) × 2.35m (Height) — wide clear-span interior supporting simultaneous 4-lane traffic and medical stretcher rollers. |
Operating Climate & Wind Ratings | Operating Temperature: -20°C to +70°C | Wind Resistance: Up to 25 m/s (Grade 8–10) |
Every 4-line CBRN decon tent can be outfitted with stainless-steel plumbing manifolds, multi-stage isolation curtains, and heavy-terrain anchoring kits to meet strict CBRN operational protocols:
System Category | Outfitting Options | Operational Benefit |
Quad Spray Piping Systems | 4-channel stainless quick-connect spray piping, multi-point overhead nozzles, and handheld rinse wands | Delivers high-volume, simultaneous washing across all 4 corridors for rapid casualty turnaround |
Multi-Zone Privacy & Isolation | Full set of longitudinal & transverse internal partition curtains and sealed passage doors | Isolates dirty (Undress), decontamination (Wash), and clean (Dress) zones across all 4 lanes |
Toxic Fluid Retention Basin | Heavy-duty 650g/m² double-sided PVC groundsheet with raised bunded edges and drainage ports | Securely traps hazardous CBRN wash runoff for controlled sump pumping and neutralization |
Anchoring & Field Stowage | High-carbon steel ground pegs, heavy-duty stakes, stainless D-rings, 1200W air pump, and heavy PVC transport bags | Guarantees rock-solid anchoring on grass, soil, or asphalt and rapid vehicle stowage |
Jinglufa manufactures certified CBRN decontamination shelters engineered for defense CBRN units, municipal emergency response agencies, hospital mass-casualty triage centers, and hazardous industrial facilities. Enhance your defense and disaster response readiness with a proven quad-corridor decontamination station built for immediate field deployment.
Ready to Configure Your 4-Line CBRN Decon Shelter System?
Provide your required Outer Tent Fabric specifications, stainless-steel plumbing connector standards, and unit quantities to receive CAD technical drawings, material test reports, and a factory-direct quotation.
[Contact Our Engineering Team for a Custom Quote & Technical Drawing]